Customization: | Available |
---|---|
Type: | Laser Distance Sensor |
Output Signal Type: | Digital Type |
Still deciding? Get samples of US$ 305.51/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
RS-485
|
PDA-CC50DGRM
|
4...20mA
|
PDA-CC50TGIM
|
Measuring range
|
80...500mm
|
Supply voltage
|
RS-485:10...30VDC;4...20mA:12...24VDC
|
Consumption power
|
≤700mW
|
Load current
|
200mA
|
Voltage drop
|
<2.5V
|
Light source
|
Red laser(650nm);Laser level:Class 2
|
Light spot
|
Φ2.5mm@500mm
|
Resolution
|
15um@80mm;500um@500mm
|
Linear accuracy
|
±0.15%F.S.(80...250mm);±0.3%F.S.(250...500mm)
|
Repeat accuracy
|
30um@80mm;250um@250mm;1000um@500mm
|
Output1
|
RS-485(Support Modbus protocol); 4...20mA(Load resistance<390Ω) |
Output2
|
PUSH-PULL/NPN/PNP And NO/NC Settable
|
Distance setting
|
RS-485:Keypress/RS-485 setting 4...20mA:Keypress setting |
Response time
|
2ms/16ms/40ms Settable
|
Dimension
|
65*51*23mm
|
Display
|
OLED Display(size:14*10.7mm)
|
Temperature drift
|
±0.02%F.S./ºC
|
Indicator
|
Power indicator:Green LED;Action indicator:Yellow LED; Alarm indicator:Yellow LED |
Protection circuit
|
Short circuit,reverse polarity,overload protection
|
Built-in function
|
Slave address & Port rate setting ;Average setting;Product self-check Analog map settings;Output setting;Restore factory settings Single point teach;Window teach;Parameter query |
Service environment
|
Operation temperature:-10…+50ºC Storage temperature:-20…+70ºC Ambient temperature:35...85%RH(No condensation) |
Anti ambient light
|
Incandescent light:<3,000lux
|
Protection degree
|
IP67
|
Material
|
Housing:Aluminum;Lens cover:PMMA;Display panel: PC
|
Vibration resistance
|
10...55Hz Double amplitude1mm,2H each in X,Y,Z directions
|
Impulse resistance
|
500m/s²(About 50G)3 times each in X,Y,Z directions
|
Connection way
|
RS-485:2m 5pins PVC cable;4...20mA:2m 4pins PVC cable
|
Accessory
|
Screw(M4×35mm)×2,Nut×2, Washer×2,Mounting bracket,Operation manual
|
Remark
|
1. Test conditions:Standard data at 23 ± 5 ºC ;Supply voltage 24VDC;30 minutes' warmup before test;Sampling period 2ms;Average sampling times 100;Standard sensing object 90% white card
2. The statistical data follows the 3σ criteria
3. Repeat accuracy:23 ± 5 ºC environment,90% reflectivity white card,100 test data results
4. Slave address,baud rate setting only for RS-485 series
5. Protecion circuit only for switch output
6. Product operation steps and precautions in "Operation manual"
|